Electrical data

  • Nominal input voltage 220…240 V
  • Mains frequency 50…60 Hz
  • Input voltage AC 220…240 V
  • Total harmonic distortion < 30 %
  • Power factor λ 0.95
  • ECG efficiency >87 %
  • Device power loss 2.6 W
  • Inrush current < 16 A
SKU: LEDOELD15 Category:

LED Driver Osram Element LD 15/220-240/350 VS20 Non-Dimmable Driver

LED Driver Osram Element LD 15/220-240/350 VS20 Non-Dimmable Driver

Spesifikasi

Electrical data

  • Nominal input voltage 220…240 V
  • Mains frequency 50…60 Hz
  • Input voltage AC 220…240 V
  • Total harmonic distortion < 30 %
  • Power factor λ 0.95
  • ECG efficiency >87 %
  • Device power loss 2.6 W
  • Inrush current < 16 A
  • Max. ECG no. on circuit breaker 10 A (B) 32
  • Max. ECG no. on circuit breaker 16 A (B) 50
  • Max. ECG no. on circuit breaker 25 A (B) –
  • Surge capability (L/N-Ground) 1 kV
  • Surge capability (L-N) 0.5 kV
  • Nominal output voltage 21…42 V
  • U-OUT (working voltage) 60 V
  • Nominal output current 350 mA
  • Output current tolerance ±10 %
  • Output ripple current (100 Hz) 40 %
  • Nominal output power 15 W
  • Galvanic isolation SELV

Dimensions & weight

  • Length 115.0 mm
  • Width 45.0 mm
  • Height 25.0 mm
  • Mounting hole spacing, length 105.0 mm
  • Mounting hole spacing, width 33.0 mm
  • Product weight 90.00 g
  • Cable cross-section, input side 0.5…1.5 mm²
  • Cable cross-section, output side 0.5…1.5 mm²
  • Wire preparation length, input side 8.0…9.0 mm
  • Wire preparation length, output side 8.0…9.0 mm

Colors & materials

  • Casing material Plastic

Temperatures & operating conditions

Ambient temperature range -10…+50 °C
Maximum temperature at tc test point 75 °C
Max.housing temperature in case of fault 110 °C
Permitted rel. humidity during operation 5…85 %

Lifespan

  • ECG lifetime 30000 h

Additional product data

  • Encapsulated No

Capabilities

  • Dimmable No
  • Overheating protection Automatic switch off, reversible by manual mains reset
  • Overload protection Automatic switch off, reversible by manual mains reset
  • Short-circuit protection Automatic reversible
  • No-load proof Yes
  • Max. cable length to lamp/LED module 2.0 m
  • Suitable for fixtures with prot. class I / II
  • Type of connection, output side Push terminal

Certificates & standards

  • Approval marks – approval CCC / CE / ENEC 10 / RCM
  • Standards Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to IEC 62384/Acc. to IEC 61000-3-2/Acc. to CISPR 15/Acc. to IEC 61000-3-3/Acc. to IEC 61547
  • Protection class II
  • Type of protection IP20

Logistical data

  • Temperature range at storage -10…75 °C

Distributor Osram